المنشورات و المؤلفات
Papillon–Lefevre syndrome (PLS) (OMIM: 245000) is a rare disease characterized by severe periodontitis and palmoplantar keratoderma. It is caused by mutations in both alleles of the cathepsin C (CatC) gene CTSC that completely abrogate the...
Abstract
Objective: To compare the clinical and radiographic parameters around short (6 to 8 mm in length) and long (11 mm in length) dental implants placed in patients with and without type 2 diabetes mellitus (T2DM).Material and Methods: Forty-...
Abstract Background: There are no studies that have compared the clinical and radiographic status around immediately-loaded (IL) and conventional loaded (CL) implants placed in patients with type 2 diabetes mellitus (T2DM).Objective: The aim was to...
The purpose of this in vitro study was to compare the primary stability and removal torque of bone level and tissue level implants in different bone quality. Fifteen tissue level and bone level implants (3.3x10mm and 4.1x10mm) were used for...
Abstract: Calcium phosphate (CaP) ceramic coatings have been used to enhance the biocompatibility and osteoconductive properties of metallic implants. The chemical composition of these ceramic coatings is an important parameter, which can influence...
Abstract
Objectives: The implant design and surface modification are independent conditions that can alter the implant bone response. The objective of this study is to compare the bone response to roughened tapered and cylindrical screw–type...
Abstract
Objectives: The aims of this study were (i) to determine the spatial resolution and sensitivity of micro- versus nano-computed tomography (CT) techniques and (ii) to validate micro- versus nano- CT in a dog dental implant model, comparative...
Abstract
Objectives: Although titanium is commonly used as a favorable bone implant material due to its mechanical properties, its bioactive and osteoconductive capacity is relatively low. Calcium phosphate ceramics, predominantly hydroxyapatite (HA...
The purpose: The aim of this in-vitro pilot study was to evaluate the effect of steam autoclaving
of the implant analog and impression coping on the accuracy of impression procedure. Materials
and methods: A master casts model was constructed, with...
Papillon-Lefevre syndrome (PLS) is a rare autosomal recessive disorder characterized by diffuse palmoplantar keratoderma and precocious aggressively progressing periodontitis, leading to the premature loss of deciduous and permanent teeth. Full...
Purpose: This study compared osseointegration of implants placed 14 days after implant site preparation with that of immediately placed implants in rabbit femurs. Materials and Methods: Implants were placed bilaterally in the femoral condyles of 12...
Abstract
Objective: The current study aimed to evaluate the osteogenic potential of electrosprayed organic
and non-organic surface coatings in a gap-implant model over 4 and 12 weeks of implantation
into the dog mandible.
Material and methods:...
Abstract: Preterm (PT) and Low birth weight (LBW) are considered to be the most relevant biological determinants of newborn infants survival, both in developed and in developing countries. Numerous risk factors for PT and LBW have been defined in...
To study the osseointegration of dental implants placed in Beagle dogs using an adapted surgical technique and to compare it with conventional method by estimating implant stability by Resonance Frequency Analysis (RFA) Dental implants were placed...
Abstract
Objective: To study the osseointegration of dental implants placed with a modified surgical technique
in Beagle dogs and to compare it with the conventional method.
Materials and methods: Dental implants were placed bilaterally in the...
The benefits of full mouth implant reconstruction include increased chewing ability, bone preservation, improved speech and an improved aesthetic for an edentulous patient. Full mouth rehabilitation for a medically compromised patient is complex and...
Abstract
Objectives: The objectives of this in vitro study were to investigate the sensitivity and
reliability of the Osstell_ systems (Resonance Frequency Analysis – RFA) compared to the Periotest
_ system in implant bone simulated conditions....
The objective of this study was to evaluate the reliability of dental personnel and patients inascertaining the shade of natural teeth compared to the electronic shade matching devices. Five groups(10 each) of participants were selected:...
The objectives of this study were to evaluate the interreter repeatbility in shade matching procedure, and to determine if differences exist in selection of particular common shades. Five groups (10 each) of participants were selected:...
