Skip to main content
User Image

أمــل بنت محمد بن عبدالعزيز المحيميد

Associate Professor

استاذ مشارك- مساعدة وكيلة كلية العلوم للدراسات العليا والبحث العلمي

كلية العلوم
مبنى 5- الدور الثالث- مكتب رقم 188
publication
Journal Article
2012

New Coated Wire Sensors for Potentiometric Determination of Gemifloxacin in Pure Form, Pharmaceutical Formulations and Biological Fluids

, Amal M. Al-Mohaimeed*, Salma A. Al-Tamimi, . 2012

ورقة بحثيه

A simple, accurate and precise potentiometric method was developed for the determination of gemifloxacin mesylate (GFX). Three ion selective coated wire sensors have been constructed from the incorporation of (GFX) with the ion-pairing agents phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and Ammonium reineckate salt (ARS). The three sensors show nearly Nernestian response over the concentration range 1.0x10−7-1.0 x10−2 mol L-1 of the drug with slopes of 56.14±0.08, 57.66±0.14 and 55.06±0.32 mV decade-1 for (GFX-PTA), (GFX-PMA) and (GFX-ARS) coated wire sensors, respectively. The electrodes exhibit a fast dynamic response of 30, 15 and 20 s for a period of 30, 35 and 25 days for  (GFX-PTA), (GFX-PMA) and (GFX-ARS) coated wire sensors, respectively. The sensors exhibit good selectivity for GFX with respect to some inorganic cations, amino acids and some pharmacologically related compounds. The electrodes display stable potential response in the pH range 6-9 which indicates the applicability of these electrodes in the specified range. The method is accurate and precise as indicated by the mean % recoveries 99.49±0.52, 99.56±0.41 and 99.41±0.45 for (GFX-PTA), (GFX-PMA) and (GFX-ARS) coated wire sensors, respectively. The proposed method was successfully applied for the determination of GFX in pure form, its pharmaceutical formulations and biological fluid

Publication Work Type
دكتوراه
Volume Number
7
Issue Number
7
Magazine \ Newspaper
International Journal of ELECTROCHEMICAL SCIENCE
Pages
12518 - 12530
more of publication
publications

: A simple, rapid and highly sensitive spectrofluorimetric method was developed for determination of gemifloxacin mesylate (GFX) in tablets. The method is based on measuring the native fluorescence…

by Amal M. Al-Mohaimeed*, Salma A. Al-Tamimi, , Nawal A. Alarfaj, Fatma A. Aly
2014
publications

A simple, accurate and precise potentiometric method was developed for the determination of gemifloxacin mesylate (GFX). Three ion selective coated wire sensors have been constructed from the…

by Amal M. Al-Mohaimeed*, Salma A. Al-Tamimi, , Nawal A. Alarfaj, Fatma A. Aly
2012
publications

 

by Salma A. Al-Tamimi, Amal M. Al-Mohaimeed*, Nawal A. Alarfaj, Fatma A. Aly
2013